Mfg Part Number: 204-18572-4 | Alternate P/N: 204185724 | Manufacturer: The Boeing Company |
NSN : 5925-01-253-2762 | Item Name : Circuit Breaker | CAGE Code : 81205 |
FSC : 5925 Circuit Breakers |
On Stacked Aviation, we can help customers procure all the NSN components that they need with ease, including those such as NSN 5925-01-253-2762 by The Boeing Company. This Circuit Breaker part is listed alongside the part number 204-18572-4, and it is currently available for purchase from our website at any time. If you would like a quote on this item for your comparisons, we ask you to fill out and submit the RFQ form as provided below. As you complete our form, please provide us with as much detail as you can regarding your particular needs so that we may best personalize a solution that accommodates your individual requirements.
As an AS9120B, ISO 9001:2015, and FAA AC 00-56B certified and accredited enterprise, we go above and beyond to ensure that every part you purchase is of the highest quality. With this promise, we choose to only work with leading global manufacturers that we trust, including those such as The Boeing Company. Additionally, we list our items with all necessary details so that you can always be sure that you are purchasing exactly what you need. As such, many items are listed alongside their CAGE Code, such as how NSN 5925-01-253-2762 is listed as an item being produced under the CAGE Code 81205. Get started on the part procurement process and experience how we can serve as your strategic sourcing partner today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-253-2762 Item Description: Circuit Breaker | 5925 | 012532762 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
204-18572-4 | 5 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
SR-1 | MFR SOURCE CONTROLLING REFERENCE | 204-18572-4 |
CRTK | SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS |
SR-1 | SPEC/STD CONTROLLING DATA | |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
ADAQ | BODY LENGTH | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SALT SPRAY PROOF |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AKPX | POLE QUANTITY | 3 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
APNQ | III ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 2.5 AC AND 1.0 DC |
CMLP | THREAD QUANTITY PER INCH | 32 |
ADAT | BODY WIDTH | 2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
SR-1 | MANUFACTURERS CODE | 81205 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 60.0 AMPERES AC AND 60.0 AMPERES DC ALL LOCATIONS |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AJEC | BOSS HEIGHT | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 50.0 DC |
CPRQ | RESET METHOD | MANUAL |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 65.0 DC ALL LOCATIONS |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
THSD | THREAD SERIES DESIGNATOR | UNC |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.200 MINIMUM AT 200 PCT AND 3.500 MAXIMUM AT 200 PCT ALL LOCATIONS |
ADTV | CASE MATERIAL | PLASTIC |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |