Mfg Part Number: 62-001 | Alternate P/N: 62001 | Manufacturer: Polara Engineering Inc |
NSN : 5915-00-531-5216 | Item Name : Filter Low Pass | CAGE Code : 32155 |
FSC : 5915 Filters and Networks |
On Stacked Aviation, we can help customers procure all the NSN components that they need with ease, including those such as NSN 5915-00-531-5216 by Polara Engineering Inc. This Filter Low Pass part is listed alongside the part number 62-001, and it is currently available for purchase from our website at any time. If you would like a quote on this item for your comparisons, we ask you to fill out and submit the RFQ form as provided below. As you complete our form, please provide us with as much detail as you can regarding your particular needs so that we may best personalize a solution that accommodates your individual requirements.
As an AS9120B, ISO 9001:2015, and FAA AC 00-56B certified and accredited enterprise, we go above and beyond to ensure that every part you purchase is of the highest quality. With this promise, we choose to only work with leading global manufacturers that we trust, including those such as Polara Engineering Inc. Additionally, we list our items with all necessary details so that you can always be sure that you are purchasing exactly what you need. As such, many items are listed alongside their CAGE Code, such as how NSN 5915-00-531-5216 is listed as an item being produced under the CAGE Code 32155. Get started on the part procurement process and experience how we can serve as your strategic sourcing partner today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-531-5216 Item Description: Filter Low Pass | 5915 | 005315216 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
62-001 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 9.875 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.375 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.500 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0/+85.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST LOW PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND LOW PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD LOW PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH LOW PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST LOW PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND LOW PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD LOW PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH LOW PASS |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST LOW PASS |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND LOW PASS |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD LOW PASS |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH LOW PASS |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED HOLE |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 1ST LOW PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 2ND LOW PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 3RD LOW PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 4TH LOW PASS |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 PIN INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 PIN OUTPUT 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 26.00 MEGAHERTZ 1ST LOW PASS AND 30.00 MEGAHERTZ 1ST LOW PASS AND 34.00 MEGAHERTZ 1ST LOW PASS AND 38.00 MEGAHERTZ 1ST LOW PASS |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 26.00 MEGAHERTZ 2ND LOW PASS AND 30.00 MEGAHERTZ 2ND LOW PASS AND 34.00 MEGAHERTZ 2ND LOW PASS AND 38.00 MEGAHERTZ 2ND LOW PASS |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 26.00 MEGAHERTZ 3RD LOW PASS AND 30.00 MEGAHERTZ 3RD LOW PASS AND 34.00 MEGAHERTZ 3RD LOW PASS AND 38.00 MEGAHERTZ 3RD LOW PASS |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 26.00 MEGAHERTZ 4TH LOW PASS AND 30.00 MEGAHERTZ 4TH LOW PASS AND 34.00 MEGAHERTZ 4TH LOW PASS AND 38.00 MEGAHERTZ 4TH LOW PASS |
CQJX | NOMINAL THREAD SIZE | 0.086 INCHES |
CQRG | BODY MATERIAL | METAL |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM 1ST LOW PASS AND 40.0 MAXIMUM 1ST LOW PASS |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM 2ND LOW PASS AND 40.0 MAXIMUM 2ND LOW PASS |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM 3RD LOW PASS AND 40.0 MAXIMUM 3RD LOW PASS |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM 4TH LOW PASS AND 40.0 MAXIMUM 4TH LOW PASS |